Found 90 products for "

endoscope repair service

"
Qualità Tappo Bilanciamento del Bianco Originale New Olympus MH-155 per Endoscopi Flessibili Fabbrica

Tappo Bilanciamento del Bianco Originale New Olympus MH-155 per Endoscopi Flessibili

Original New Olympus MH-155 White Balance Cap For Flexible Endoscopes ► Brief Description Olympus MH-155 Used to set the accurate white balance for the endoscope's camera system before a procedure. This ensures that the colors of tissues and organs viewed during endoscopy are displayed correctly on ...

Qualità Cappuccio resistente all'acqua MH-553 per endoscopi video flessibili Olympus Fabbrica

Cappuccio resistente all'acqua MH-553 per endoscopi video flessibili Olympus

Water-Resistant Cap MH-553 For Olympus Flexible Video Endoscopes ► Brief Description The Olympus MH-553 is a critical accessory used in medical endoscopy, specifically designed as a Water-Resistant Cap (also known as a Soaking Cap or Leak Test Cap). Its primary purpose is to protect the sensitive ...

Qualità Valvola aria-acqua MAJ-1444 per l'endoscopio flessibile Olympus Fabbrica

Valvola aria-acqua MAJ-1444 per l'endoscopio flessibile Olympus

Air Water Valve MAJ-1444 ► Brief Description The Olympus MAJ-1444 is an Air/Water Valve primarily used with Olympus Ultrasonic Endoscopes (EUS - Endoscopic Ultrasound). This valve plays a crucial role during endoscopy procedures, enabling the controlled delivery of air and water to the endoscope's ...

Qualità Mag-1443 Parti di endoscopi flessibili per endoscopi Olympus Valvola di aspirazione Fabbrica

Mag-1443 Parti di endoscopi flessibili per endoscopi Olympus Valvola di aspirazione

Detail olympus suction valve maj-1443 for eus endoscopes Olympus SUCTION VALVE MAJ-1443 Brand: Olympus Series: SUCTION VALVE Model:MAJ-1443 Description .Suction Valve, Autoclavable, Non-Sterile, Reusable, For EUS Endoscopes . Helps prevent backflow . Reusable CareUtech is the global provider of ...

Qualità Processore video PENTAX Medical EPK-i7000 per riparazione Fabbrica

Processore video PENTAX Medical EPK-i7000 per riparazione

PENTAX Medical EPK-i7000 Video Processor For Repair ► Brief Description Brand: PENTAX (PENTAX Endoscope Processor) Model: EPK-i7000 Serial Number: AC*** Fault: It cannot recognize the endoscope and reports an error. Solution: Repair the system board. Repair Time: 3-5 working days. Warranty Period: ...

Qualità Olympus A70940A Artroscopio autoclavabile da riparare Fabbrica

Olympus A70940A Artroscopio autoclavabile da riparare

Olympus A70940A Autoclavable Arthroscope for repair ► Brief Description Fault: 1. Image blur, black dots and dark. 2. Fiber not light enough. 3. Rod lens broken. 4. Objective lens broken and dirty. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens ...

Qualità Olympus A4674A Isteroscopio autoclavabile da riparare Fabbrica

Olympus A4674A Isteroscopio autoclavabile da riparare

Olympus A4674A Autoclavable Hysteroscope for repair ► Brief Description Fault: 1. Image blur and black shadow. 2. Rod lens broken. 3. Outer tube bending and transformation. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the ...

Qualità Karl Storz 27005BA Cystoscope for repair Fabbrica

Karl Storz 27005BA Cystoscope for repair

Karl Storz 27005BA Cystoscope for repair ► Brief Description Fault: 1. No image. 2. Fiber abrasion. 3. Rod lens broken and cracked. 4. Objective lens broken and dirty. 5. Eyepiece cover broken. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens ...

Qualità Equipaggiamento medico Olympus riparato soluzione definitiva per i servizi medici Fabbrica

Equipaggiamento medico Olympus riparato soluzione definitiva per i servizi medici

Product Description: Product Summary: The Medical Device Repair Cases product offered is a comprehensive solution for repairing and maintaining Olympus medical devices. With a warranty of 90 days, customers can have peace of mind knowing that their repaired devices are covered for an extended period...