Qualità Cappuccio resistente all'acqua MH-553 per endoscopi video flessibili Olympus Fabbrica

Cappuccio resistente all'acqua MH-553 per endoscopi video flessibili Olympus

Water-Resistant Cap MH-553 For Olympus Flexible Video Endoscopes ► Brief Description The Olympus MH-553 is a critical accessory used in medical endoscopy, specifically designed as a Water-Resistant Cap (also known as a Soaking Cap or Leak Test Cap). Its primary purpose is to protect the sensitive electrical connectors of a flexible endoscope during the cleaning, disinfection, and sterilization processes. ► Features Water Ingress Protection Leakage Testing Support Reprocessing

Qualità Processore video PENTAX Medical EPK-i7000 per riparazione Fabbrica

Processore video PENTAX Medical EPK-i7000 per riparazione

PENTAX Medical EPK-i7000 Video Processor For Repair ► Brief Description Brand: PENTAX (PENTAX Endoscope Processor) Model: EPK-i7000 Serial Number: AC*** Fault: It cannot recognize the endoscope and reports an error. Solution: Repair the system board. Repair Time: 3-5 working days. Warranty Period: Six months. ►Problem & Solution Brand PENTAX Model EPK-i7000 Product Processor Fault It cannot recognize the endoscope and reports an error. Solution Repair the system board. ►

Qualità Mag-1443 Parti di endoscopi flessibili per endoscopi Olympus Valvola di aspirazione Fabbrica

Mag-1443 Parti di endoscopi flessibili per endoscopi Olympus Valvola di aspirazione

Detail olympus suction valve maj-1443 for eus endoscopes Olympus SUCTION VALVE MAJ-1443 Brand: Olympus Series: SUCTION VALVE Model:MAJ-1443 Description .Suction Valve, Autoclavable, Non-Sterile, Reusable, For EUS Endoscopes . Helps prevent backflow . Reusable CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound,

Qualità Valvola aria-acqua MAJ-1444 per l'endoscopio flessibile Olympus Fabbrica

Valvola aria-acqua MAJ-1444 per l'endoscopio flessibile Olympus

Air Water Valve MAJ-1444 ► Brief Description The Olympus MAJ-1444 is an Air/Water Valve primarily used with Olympus Ultrasonic Endoscopes (EUS - Endoscopic Ultrasound). This valve plays a crucial role during endoscopy procedures, enabling the controlled delivery of air and water to the endoscope's distal tip. ► Features Air Insufflation Water Jet/Washing Cleaning the Objective Lens Washing the Examination Area Balloon Inflation (for EUS probes) One-Way Valve Functionality

Qualità Olympus A70940A Artroscopio autoclavabile da riparare Fabbrica

Olympus A70940A Artroscopio autoclavabile da riparare

Olympus A70940A Autoclavable Arthroscope for repair ► Brief Description Fault: 1. Image blur, black dots and dark. 2. Fiber not light enough. 3. Rod lens broken. 4. Objective lens broken and dirty. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Clean and install the optical path, check the image. 8. Seal with endoscope and test. ►Problem & Solutoin Brand Olympus Model

Qualità Olympus A4674A Isteroscopio autoclavabile da riparare Fabbrica

Olympus A4674A Isteroscopio autoclavabile da riparare

Olympus A4674A Autoclavable Hysteroscope for repair ► Brief Description Fault: 1. Image blur and black shadow. 2. Rod lens broken. 3. Outer tube bending and transformation. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Clean and install the optical path, check the image. 8. Seal with endoscope and test. ►Problem & Solutoin Brand Olympus Model A4674A Fault 1. Image blur

Qualità Karl Storz 27005BA Cystoscope for repair Fabbrica

Karl Storz 27005BA Cystoscope for repair

Karl Storz 27005BA Cystoscope for repair ► Brief Description Fault: 1. No image. 2. Fiber abrasion. 3. Rod lens broken and cracked. 4. Objective lens broken and dirty. 5. Eyepiece cover broken. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Replace eyepiece cover. 8. Clean and install the optical path, check the image. 9. Seal with endoscope and test. ►Problem & Solutoin

Qualità Casse di riparazione di apparecchiature mediche di Olympus CF-H190L Colonoscopio da riparare Fabbrica

Casse di riparazione di apparecchiature mediche di Olympus CF-H190L Colonoscopio da riparare

Olympus CF-H190L Colonoscope for repair,SN:261****. Fault:Light bundle broken,biopsy tube worn,water air tube leakage,bending section deformation,wire helix tube worn. Solution:Replace the bending section,wire,helix tube,air tube and rubber.PS:Warranty for replace parts only. Repair time:7 working days. Repair price:$****. Warranty:90 days. Guangzhou Care techonoly Co., Ltd. is a company dedicated to the supply of medical equipment maintenance tools, maintenance accessories,

Qualità Casse per la riparazione di dispositivi medici di GE RIC5-9-D Fabbrica

Casse per la riparazione di dispositivi medici di GE RIC5-9-D

GE RIC5-9-D Probe Fault: Dome loose, straight relief tiny broken, with error on machine. Solution: Replace dome and oiling. Repair cost : $***. Common Issues with the GE RIC5-9-D Ultrasound Probe: Image Artifacts/Dropouts: These can manifest as lines, shadowing, or a complete loss of image in certain areas. Common causes include: Crystal Damage: Piezoelectric crystals within the transducer array can become damaged due to physical impact, overheating, or degradation over time.