Qualità Lenti a guida luminosa per Olympus BF-P290 EVIS LUCERA ELITE Video broncoscopio Fabbrica

Lenti a guida luminosa per Olympus BF-P290 EVIS LUCERA ELITE Video broncoscopio

Light Guide Lens For Olympus BF-P290 EVIS LUCERA ELITE Video Bronchoscope ► Brief Description The Olympus BF-P290 is an advanced video bronchoscope designed to enhance diagnostic and therapeutic procedures in the respiratory system. ► Features High-Quality Imaging Narrow Band Imaging (NBI) Ultra-Slim Design 2.0 mm Instrument Channel Wide Angulation Range Insertion Tube Rotation Function One-Touch Waterproof Connector Compatibility with EVIS LUCERA ELITE System ► Specification

Qualità Storz Wolf Rod Lens Endoscopio rigido Parti in magazzino In vendita Fabbrica

Storz Wolf Rod Lens Endoscopio rigido Parti in magazzino In vendita

Detail Rod Lens: Brand Size(4mm) Storz 2.76*29 Stryker 2.68*21 Olympus 2.76*21.4 Wolf 2.76*274MM, 10MM all provided. Spare parts for Rigid Endoscope: Rod lens,Objective lens,Rings,Glass,Eyepiece & Cover, Outer tube & Inner tube,Fiber,etc. More information just feel free to contact us. Guangzhou Care techonoly Co., Ltd. is a company dedicated to the supply of medical equipment maintenance tools, maintenance accessories, professional maintenance training and maintenance

Qualità Endoscopio Karl Storz 27005BA per riparazione Fabbrica

Endoscopio Karl Storz 27005BA per riparazione

Karl Storz 27005BA endoscope for repair ► Brief Description Fault: 1. No image. 2. Fiber abrasion. 3. Rod lens broken and cracked. 4. Objective lens broken and dirty. 5. Eyepiece cover broken. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Replace eyepiece cover. 8. Clean and install the optical path, check the image. 9. Seal with endoscope and test. ►Problem & Solutoin

Qualità Gastroscopio Olympus GIF-H170 per riparazione Fabbrica

Gastroscopio Olympus GIF-H170 per riparazione

Olympus GIF-H170 gastroscope for repair ► Brief Description Fault: 1. The top left and middle right side with blur image, objective Lens broken. 2. 20% light bundle broken, the small lens turned yellow. 3. Insert tube yellow and wrinkles. 4. The biopsy tube abrasion. 5. The wire and helix tube abrasion. 6. Light guide tube aging and wrinkle. Solution: Replace objective lens, light bundle, small lens, insert tube, biopsy tube, wires, helix tube, light guide tube and rubber.

Qualità Olympus A70940A Artroscopio autoclavabile da riparare Fabbrica

Olympus A70940A Artroscopio autoclavabile da riparare

Olympus A70940A Autoclavable Arthroscope for repair ► Brief Description Fault: 1. Image blur, black dots and dark. 2. Fiber not light enough. 3. Rod lens broken. 4. Objective lens broken and dirty. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Clean and install the optical path, check the image. 8. Seal with endoscope and test. ►Problem & Solutoin Brand Olympus Model

Qualità Karl Storz 27005BA Cystoscope for repair Fabbrica

Karl Storz 27005BA Cystoscope for repair

Karl Storz 27005BA Cystoscope for repair ► Brief Description Fault: 1. No image. 2. Fiber abrasion. 3. Rod lens broken and cracked. 4. Objective lens broken and dirty. 5. Eyepiece cover broken. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Replace eyepiece cover. 8. Clean and install the optical path, check the image. 9. Seal with endoscope and test. ►Problem & Solutoin

Qualità Colonoscopio Olympus CF-240L per la riparazione Fabbrica

Colonoscopio Olympus CF-240L per la riparazione

Olympus CF-240L Colonoscope for repair ► Brief Description Fault: Leakage, glass of light bundle blur, rubber leak, angle not enough,image fuzzle,objective lens scratch. Solution: Replace rubber, objective lens, C cover. Adjust the angle. ►Problem & Solutoin Brand Olympus Model CF-240L Fault Leakage, glass of light bundle blur, rubber leak, angle not enough, image fuzzle,objective lens scratch, Solution Replace rubber, objective lens, C cover. Adjust the angle. ► Common

Qualità Stryker 30º 0502-503-030 laproscope for repair Fabbrica

Stryker 30º 0502-503-030 laproscope for repair

Stryker 30º 0502-503-030 laproscope for repair ► Brief Description Fault: Image blur, objective lens loose without glue, inner optical parts broken. Solution: Add glue for objective lens, replace inner optical parts, clean and adjust optical system, seal with eyepiece. ►Problem & Solutoin Brand Stryker Model 0502-503-030 Fault Image blur, objective lens loose without glue, inner optical parts broken. Solution Add glue for objective lens, replace inner optical parts, clean and

Qualità Olympus A4674A Isteroscopio autoclavabile da riparare Fabbrica

Olympus A4674A Isteroscopio autoclavabile da riparare

Olympus A4674A Autoclavable Hysteroscope for repair ► Brief Description Fault: 1. Image blur and black shadow. 2. Rod lens broken. 3. Outer tube bending and transformation. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Clean and install the optical path, check the image. 8. Seal with endoscope and test. ►Problem & Solutoin Brand Olympus Model A4674A Fault 1. Image blur