Found 90 products for "

endoscope repair

"
Qualità Olympus CF-H190L Colonoscopio per la riparazione Fabbrica

Olympus CF-H190L Colonoscopio per la riparazione

Olympus CF-H190L Colonoscope for repair ► Brief Description Fault: 1. Image ok; 2. Light bundle still ok; 3. The front end of the insert tube is broken, and the serpentine; the position of stress boot is leaking; 4. Biopsy tube wear; 5. Left Angle failure, bending section, wire and helix tube wear; ...

Qualità Gastroscopio Olympus GIF-Q180 per riparazione Fabbrica

Gastroscopio Olympus GIF-Q180 per riparazione

Olympus GIF-Q180 gastroscope for repair ► Brief Description Fault: 1.image definition not enough, CCD aging. 2.30% light bundle broken. 3. Insert tube aging and wrinkle. 4.Biopsy tube abrasion. 5. Bending section bited, transformation. 6. Angle not enough, wires and helix tube abrasion. 7. Light ...

Qualità GIF-XQ240 Gastroscopio da Olympus per la riparazione Fabbrica

GIF-XQ240 Gastroscopio da Olympus per la riparazione

GIF-XQ240 Gastroscope by Olympus for repair ► Brief Description Fault: Leakage. Solution: Replace light guide tube,NO.1 button,wire,mesh,adjust angle. ►Problem & Solutoin Brand Olympus Model GIF-XQ240 Fault Leakage. Solution Replace light guide tube,NO.1 button,wire,mesh,adjust angle. ► Common ...

Qualità Formazione per la riparazione di apparecchiature mediche ad endoscopio flessibile Fabbrica

Formazione per la riparazione di apparecchiature mediche ad endoscopio flessibile

The courses we organize and their contents are as follows. COURSE: Flexible Endoscope Repair Training Course Brands: OLYMPUS, FUJINON Gastroscope, Colonoscope, Duodenoscope, Bronchoscope, Fiberscope, Enteroscope, Hysteroscope Duration: 5 Days / 4 hours per day (20 hours total) Course Schedule: ...

Qualità Parti di endoscopi flessibili Pentax EG-2990i Gastroscopi CCD Fabbrica

Parti di endoscopi flessibili Pentax EG-2990i Gastroscopi CCD

Product Description: The Flexible Endoscope Repair Tool is a brand new product designed for repairing flexible endoscopes, specifically the Pentax EG-2990i gastroscope model. This repair tool is made with high-quality materials to ensure long-lasting use, making it a durable and reliable solution ...

Qualità T-R0037 Endoscopio di riparazione per il tornio di perforazione Wolf Storz Fabbrica

T-R0037 Endoscopio di riparazione per il tornio di perforazione Wolf Storz

Product Description 1. Introduction T-R0037 Repair tool for Storz Wolf Olympus Stryker Rigid Endoscope Drilling Lathe Brand-new Perfectly repair rigid endoscope without scratch 2. Characteristics and Advantages Number:T-R0037 Features: Durable, Portable, Multi-functional Advantages: High Quality ...

Qualità T-R0027 Riparazione a portata rigida per strumento di rettifica ad angolo di Storz Wolf Fabbrica

T-R0027 Riparazione a portata rigida per strumento di rettifica ad angolo di Storz Wolf

Product Description 1. Introduction T-R0027 Repair tool for Storz Wolf Olympus Stryker Rigid endoscope Angle Grinding Tool Brand-new Perfectly repair rigid endoscope without scratch 2. Characteristics and Advantages Number:T-R0027 Features: Durable, Portable, Multi-functional Advantages: High ...

Qualità OLYMPUS CF-HQ190L Casse per la riparazione di dispositivi medici Casse per la riparazione di attrezzi Fabbrica

OLYMPUS CF-HQ190L Casse per la riparazione di dispositivi medici Casse per la riparazione di attrezzi

OLYMPUS CF-HQ190L Repair Problem: 1, Image display;2, Light bundle broken about 10%;3, Insertion tube is ok;4, Biospy channel worn and leaking;5, The upper angle broken, helix tube and bending section were worn;6, Light guide tube indented and the back cover is leaking;7, The EL-connector is not ...

Qualità Flessibile Endoscopio Parti Olympus MB-155 Leakage Tester Fabbrica

Flessibile Endoscopio Parti Olympus MB-155 Leakage Tester

Olympus MB-155 Leakage Tester ► Brief Description The Olympus MB-155 Leakage Tester is a critical accessory in the proper reprocessing of Olympus flexible endoscopes. It is used to ensure the integrity of the endoscope's outer sheath and internal channels, preventing costly fluid invasion and ...