Found 101 products for "

camera head parts

"
Qualità Stryker Maryland Dissector 250-080-578. Fabbrica

Stryker Maryland Dissector 250-080-578.

Brand: STRYKER Model: 250-080-578 Description: It's a 5mm diameter and 45cm long Maryland dissector forceps with double action. Use: Primarily used in laparoscopic procedures for grasping, dissecting, and manipulating tissue. Guangzhou Care techonoly Co., Ltd. is a company dedicated to the supply of medical equipment maintenance tools, maintenance accessories, professional maintenance training and maintenance services, and serving customers in the global medical field. The

Qualità Olympus CCD per broncoscopio BF-260 per procedure mediche Fabbrica

Olympus CCD per broncoscopio BF-260 per procedure mediche

Olympus CCD for BF-260 Bronchoscope Spare parts of Olympus Spare parts for BF-P290, GIF-XP290, GIF-H290Z, CF-HQ290ZI, PCF-HQ290ZI, CF-HQ290I, JF-260V, CF-V70I, CF-H260AZI, GIF-V70, GIF-H260, GIF-LV1, BF-IT260, BF-260, BF-F260, BF-IT60, BF-XP260F, BF-P260F, ENF-V2, LTF-3D, CYF-VA2, CHF-V, BF-1TQ290, CYF-VHA, ENF-VH, CYF-VA2, LTF-190-10-3D, CF-H170, GIF-H170, GIF-H290, CF-H290I, CF-HQ290I, URF-V, URF-V2, ENF-V3, GIF-HQ290, BF-1T260, URF-V, PCF-H290DI, LTF-S190-10-3D, GIF-XQ260,

Qualità Olympus CCD per GIF-XQ260 Gastroscopio con serie CCD Fabbrica

Olympus CCD per GIF-XQ260 Gastroscopio con serie CCD

Olypmus CCD for GIF-XQ260 Gastroscope Spare parte of Olympus Spare parts for BF-P290, GIF-XP290, GIF-H290Z, CF-HQ290ZI, PCF-HQ290ZI, CF-HQ290I, JF-260V, CF-V70I, CF-H260AZI, GIF-V70, GIF-H260, GIF-LV1, BF-IT260, BF-260, BF-F260, BF-IT60, BF-XP260F, BF-P260F, ENF-V2, LTF-3D, CYF-VA2, CHF-V, BF-1TQ290, CYF-VHA, ENF-VH, CYF-VA2, LTF-190-10-3D, CF-H170, GIF-H170, GIF-H290, CF-H290I, CF-HQ290I, URF-V, URF-V2, ENF-V3, GIF-HQ290, BF-1T260, URF-V, PCF-H290DI, LTF-S190-10-3D, GIF

Qualità Parti di apparecchiature mediche Sonda lineare Sonoscape L743 per riparazione Fabbrica

Parti di apparecchiature mediche Sonda lineare Sonoscape L743 per riparazione

Sonoscape L743 linear probe for repair ► Brief Description Fault: Probe head broken. Solution: Replace probe head.(including crystal and upper housing). ►Problem & Solutoin Brand Sonoscape Model L743 Fault Probe head broken Solution Replace probe head.(including crystal and upper housing) ► Common issues with L743 Probes No Image or Intermittent Image Poor Image Quality Probe Not Recognized/Detected Physical Damage to the Probe Head or Cable Overheating Probe Gel Leakage If

Qualità Olympus CCD per GIF-Q260 Gastroscopio per endoscopia avanzata Fabbrica

Olympus CCD per GIF-Q260 Gastroscopio per endoscopia avanzata

Olympus CCD For GIF-Q260 Gastroscope Spare parts of Olympus Spare parts for BF-P290, GIF-XP290, GIF-H290Z, CF-HQ290ZI, PCF-HQ290ZI, CF-HQ290I, JF-260V, CF-V70I, CF-H260AZI, GIF-V70, GIF-H260, GIF-LV1, BF-IT260, BF-260, BF-F260, BF-IT60, BF-XP260F, BF-P260F, ENF-V2, LTF-3D, CYF-VA2, CHF-V, BF-1TQ290, CYF-VHA, ENF-VH, CYF-VA2, LTF-190-10-3D, CF-H170, GIF-H170, GIF-H290, CF-H290I, CF-HQ290I, URF-V, URF-V2, ENF-V3, GIF-HQ290, BF-1T260, URF-V, PCF-H290DI, LTF-S190-10-3D, GIF-XQ260

Qualità Sonda addominale GE 4C-RS da riparare Fabbrica

Sonda addominale GE 4C-RS da riparare

GE 4C-RS abdominal probe for repair ► Brief Description Fault: Lens broken, cable broken, crystal bad. Solution: Replace probe head, repair cable. ►Problem & Solutoin Bran GE Model 4C-RS Fault Lens broken, cable broken, crystal bad Solution Replace probe head, repair cable ► Common issues with 4C-RS Probe Image dropouts / Black lines Acoustic lens damage Cable damage Connector damage Oil leakage If your instrument has any of the above problems or others, please feel free to

Qualità 1898200T M4 Straightshot Microdebrider e manipolo per riparazione Fabbrica

1898200T M4 Straightshot Microdebrider e manipolo per riparazione

1898200T M4 Straightshot Microdebrider and Handpiece for repair ► Brief Description Fault: 1) The bearing is corroded and the seal is broken. 2) Motor stuck, inside is full of disinfection residue, motor corrosion. 3) The rotation direction of the knife head is stuck. 4) Handle paint off, internal corrosion.. Solution: Exchange the whole handpiece except cable. ►Problem & Solutoin Model 1898200T Fault 1) The bearing is corroded and the seal is broken. 2) Motor stuck, inside

Qualità Laringoscopio Insighters IS3-F per riparazione Fabbrica

Laringoscopio Insighters IS3-F per riparazione

Insighters IS3-F laryngoscope for repair ► Brief Description Fault: 1. Image blank screen; 2. Insert tube abrasion 3. Bending section transformation; 4. Distal head transformation; Solution: Replace CCD, insert tube, bending section, rubber ►Problem & Solutoin Brand Insighters Model IS3-F Fault 1. Image blank screen; 2. Insert tube abrasion 3. Bending section transformation; 4. Distal head transformation; Solution Replace CCD, insert tube, bending section, rubber ► Common

Qualità T-R0035 Specialista in riparazione di endoscopia per Olympus Stryker Bench Vice Fabbrica

T-R0035 Specialista in riparazione di endoscopia per Olympus Stryker Bench Vice

Product Description 1. Introduction T-R0035 Repair tool for Storz Wolf Olympus Stryker Rigid Endoscope Bench Vice Brand-new Perfectly repair rigid endoscope without scratch 2. Characteristics and Advantages Number:T-R0035 Features: Durable, Portable, Multi-functional Advantages: High Quality Materials, Precise Design, Easy To Use Main Material: Iron Weight: 10KG 3.Functions: Disassembly and assembly 4.Quality and Reliability High-quality iron raw materials CNC machined